Digital Handheld Multifunction Process Calibrator YHS-724 , volts / mA / RTDs / frequency / ohms
Quick Detail:
Easy to read measure/source screen lets you view input and output simultaneously
Measure volts, mA, RTDs, thermocouples and ohms to test sensors and transmitters
Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
Support flow meter testing with frequency and CPM functions
Perform fast linearity tests with auto- step and auto-ramp features
Power transmitters during test using loop supply with simultaneous mA measurement
Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms
Store frequently used test setups for later use
Large battery capacity of four AA cells ;Battery door for easy changes
A split-screen display. The upper display allows users to measure volts, current, and only. The lower display allows the user to measure and source volts, current , resistance temperature detectors, thermocouples and ohms.
A thermocouple (TC) input/output terminal with cold junction temperature compensation, ambient temperature can be set and calibrate within the menu function.
Each parameters can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0% and 100% of the value.
In the configuration menu can be set manually : Power off time for Instrument, backlight, off time, Screen Contrast, Cold junction compensation ON/OFF, HART, resistance, ON/OFF and ETC.
Have calendar clock function, it can be calibrated in configuration menu.
It can be store 8 sets of measurement and output data and call the showing at any time, all the settings and the functions of the last operation be auto-stored after power off.
High capacity rechargeable battery pack, with power adapter, within integrated charge-management functions.
Novel shape, large screen dot-matrix graphic display
Loop Power Voltage: 24V
Accuracy: 10%
Maximum Current: 24 mA, Short-circuit protection
Measure Accuracy:
| Function | Measure Singal | Measure Accuracy | 
| 
 DC Voltage | 0.000—30.000 V | 0.02%+3 counts (The upper display) | 
| 0.000—24.000 V | 0.02%+ 3 counts (The lower display) | |
| 0.000—90.000 mV | 0.01%+ 10 counts | |
| -10.000 —80.000mV 0.01 % + 10 counts (use the thermocouple jack ) | ||
| DC Current | 0.000—24.000 mA | 0.02%+ 4 counts(The upper display) | 
| 0.000—24.000 mA | 0.02%+ 4 counts(The lower display) | |
| Resistance | 0.00— 400.00Ω | 0.1Ω (4 wire), 0.15Ω (2 wire and 3 wire) | 
| 400.0—4000.0Ω | 0.5Ω (4 wire), 1Ω (2 wire and 3 wire) | |
Output Accuracy:
| Output | Range | Accuracy | 
| DC Voltage | 0.000— 20.000 V | 0.02%+3 counts | 
| 0.000—90.000 m V | 0.01%+10 counts | |
| DC Current | 0.000—24.000 mA | 0.02%+ 4 counts | 
| Resistance | 5.00 — 400.00 Ω | 0.15 Ω (Excitation current 0.15 to 0.5 mA), 0.1Ω (Excitation current 0.5 to 2 mA) | 
| 400.0 —4000.0 Ω | 0.5Ω(Excitation current 0.05 to 0.8 mA) | 
RTD and Thermocouple:
| Type | Measure Accuracy | Output Accuracy | 
| PT-100 (385) | 0.3 °C(4 wire ), 0.5 °C(2 wire and 3 wire) | 0.3 °C | 
| PT-100 (3926) | 0.3 °C(4 wire ), 0.5 °C(2 wire and 3 wire) | 0.3 °C | 
| PT-100 (JIS) | 0.3 °C(4 wire ), 0.5 °C(2 wire and 3 wire) | 0.3 °C | 
| PT-200 (385) | 0.8 °C(4 wire ), 1.6 °C(2 wire and 3 wire) | 0.8 °C | 
| PT-500 (385) | 0.4 °C(4 wire ), 0.9 °C(2 wire and 3 wire) | 0.4 °C | 
| PT-1000 (385) | 0.2 °C(4 wire ), 0.3 °C(2 wire and 3 wire) | 0.3 °C | 
| Cu50 | 0.4 °C(4 wire ), 0.6 °C(2 wire and 3 wire) | 0.4 °C | 
| Cu100 | 0.4 °C(4 wire ), 0.6 °C(2 wire and 3 wire) | 0.4 °C | 
| J: | 0.5 °C | 0.7 °C | 
| K: | 0.8 °C | 0.8 °C | 
| T: | 0.5 °C | 0.5 °C | 
| E: | 0.5 °C | 0.5 °C | 
| R: | 1.5 °C | 1.0 °C | 
| S: | 1.5 °C | 1.5 °C | 
| B: | 1.8 °C | 1.0 °C | 
| N: | 0.8°C | 0.8 °C | 
|   | 
| Digital Handheld Multifunction Process Calibrator YHS-724 , volts / mA / RTDs / frequency / ohms Images | 
 Portable Digital Multifunction Process Calibrator with Diode Test And Continuity
                                                                                    
                        
                        
                        
                                                            Portable Digital Multifunction Process Calibrator with Diode Test And Continuity
                                                    
                        
                     Exact Current / Voltage Multifunction Process Calibrator Digital Multimeter ,
                                                                                    
                        
                        
                        
                                                            Exact Current / Voltage Multifunction Process Calibrator Digital Multimeter ,
                                                    
                        
                     High Accuracy Resolution Multifunction Process Calibrator , Anti-Dropand
                                                                                    
                        
                        
                        
                                                            High Accuracy Resolution Multifunction Process Calibrator , Anti-Dropand
                                                    
                        
                     0.05% DC Voltage Accuracy Multifunction Process Calibrator , YH-7012 Current
                                                                                    
                        
                        
                        
                                                            0.05% DC Voltage Accuracy Multifunction Process Calibrator , YH-7012 Current
                                                    
                        
                     Accuracy YHS787 Multifunction Process Calibrator ,24 / 30mA Output Voltage
                                                                                    
                        
                        
                        
                                                            Accuracy YHS787 Multifunction Process Calibrator ,24 / 30mA Output Voltage
                                                    
                        
                     RS232 Interface Relative Portable Multifunction Process Calibrator with Record
                                                                                    
                        
                        
                        
                                                            RS232 Interface Relative Portable Multifunction Process Calibrator with Record
                                                    
                        
                     Accuracy Current Multifunction Process Calibrator 1000V Overload Protection ,
                                                                                    
                        
                        
                        
                                                            Accuracy Current Multifunction Process Calibrator 1000V Overload Protection ,
                                                    
                        
                     Frequency CPM Multifunction Process Calibrator Flow Meter Testing , YHS-724
                                                                                    
                        
                        
                        
                                                            Frequency CPM Multifunction Process Calibrator Flow Meter Testing , YHS-724
                                                    
                        
                     24V Power Voltage Loop Multifunction Process Calibrator with Short-circuit
                                                                                    
                        
                        
                        
                                                            24V Power Voltage Loop Multifunction Process Calibrator with Short-circuit
                                                    
                        
                     High Accuracy Multifunction Process Calibrator , Detecting / Debugging Automatic
                                                                                    
                        
                        
                        
                                                            High Accuracy Multifunction Process Calibrator , Detecting / Debugging Automatic